Prerequisites for installation and use:
- Enki Application* + Enki Box or Enki Connect Box / Essentiel b Connect Box
* Prerequisites for the Enki application: Internet access and a phone with minimum operating system: Android: 7 / iOS: 15
Communication protocol:
- Zigbee
Available country:
- France**
**Essentiel b Connect Box available only in France
State feedback available:
- Yes
Alexa voice control:
- Not direct, but possible via manual scenarios
Google Home voice control:
- Not direct, but possible via manual scenarios
Article contents:
Technical description
Product functionality in the ENKI application
Product view
What does the radiator screen status mean?
How to calibrate my radiator?
How to reset my device?
Technical documents / user manual
Technical description:
- Type: Electric heating (750, 1000, 1500, or 2000W)
- Requires Enki box: Yes / ENKI Box V1 - ENKI Connect Box
- State feedback: Yes
- Model: PVA-029 board
- Hardware: Rev. 0
- Power: 10 dBm
- Transmission: 2.4 GHz to 2.485 GHz
- Protocol: Zigbee
- Operating temperature range: 0°C to +40°C
- Powered by: 230 V
-
Description:
- Aluminum cast radiator with flat elements. Side cladding cheeks, 1 side cheek on one side
- High-performance mineral oil, maintenance-free
- High resistance anti-corrosion protection by 11 treatment baths with cataphoresis.
- Very long-lasting epoxy paint, uniform paint on all radiator faces
- Safety guaranteed by thermal limiter
- Each Alcantara is checked at 14 manufacturing stages
- Wall projection: 106 mm
-
Regulation:
- Ultra-precise room thermostat to 1/10th of a degree
- Backlit digital LCD display
- 1 free weekly user program and 5 pre-recorded programs
- Digital consumption indicator
- Child lock system
- Window open/close detector
- Centralized time programming via 6 pilot wire commands
- Low standby consumption (0.5 W)
- Remotely controllable via the box and ENKI application
Product functionality in the ENKI application:
| Object functionality | Properties | Scenario integration | ||
| Actions | Triggers | Conditions | ||
| Change thermostat target temperature | Min: 7° / Max: 30° / Step: 0.5° | ✔ | ✘ | ✘ |
| Create an override | Temporarily change the equipment temperature for a given time when it is in a program | ✘ | ✘ | ✘ |
| Programming | Via heating menu or individually via the control board | ✘ | ✘ | ✘ |
|
|
|
| Control page | Settings |
Product view:
What does the radiator screen status mean:
|
|
|
|||
| Not paired with ENKI box | Searching for signal | Paired with ENKI box | ||
| Heating in progress | Override activated (Manual mode) |
How to calibrate my radiator?
SETPOINT TEMPERATURE CALIBRATION:
If after several days of operation of your radiator you notice a difference between the temperature measured in your room and the temperature programmed on the device, you can calibrate your radiator in increments of 0.1°C by following the procedure below.
How to reset my device?
RESET TO FACTORY SETTINGS (RESET)
When your control interface is not locked, you can return to the original settings at any time. The device then restarts in frost protection mode.