Prerequisites for installation and use:
- Enki application* + Enki Box or Enki Connect / Essentiel b Connect box
* Prerequisite for the Enki application: Internet access and a phone with a minimum operating system: Android: 7 / iOS: 15
Communication protocol:
- Zigbee
Available countries:
- France**
**Essentiel b Connect box only available in France
Status feedback available:
- Yes
Alexa voice control:
- No
Google Home voice control:
- No
Article contents:
-
Technical description
-
Operation of the product in the ENKI application
-
Product view
-
How to reset my device?
-
Technical documents / user manual
Technical description:
- Type: Electric heater (750, 1000, 1500 or 2000W)
- Requires the Enki box: Yes / Enki Box V1 - Enki Connect Box
- Status feedback: Yes
- Model: PVA-029 card
- Hardware: Rev. 0
- Power: 10 dBm
- Emission: from 2.4 GHz to 2.485 GHz
- Protocol: Zigbee
- Operating temperature range: 0°C +40°C
- Device powered at: 230 V
-
Description:
- Cast aluminum radiator with flat elements. Side cladding cheeks, 1 side cheek on 1 side
- High-performance mineral oil, maintenance-free
- High-resistance anti-corrosion protection with 11 electrophoretic treatment baths.
- Very long-lasting epoxy paint, uniform paint on all sides of the radiator
- Safety guaranteed by the thermal limiter
- Each Alcantara is controlled at 14 manufacturing steps
- Cast aluminum radiator with flat elements. Side cladding cheeks, 1 side cheek on 1 side
- Projection from wall: 106 mm
-
Regulation:
- Ultra-precise room thermostat to 1/10th of a degree
- Backlit digital LCD display
- 1 weekly user-defined program and 5 pre-recorded programs
- Digital consumption indicator
- Parental lock system
- Window open / closed detector
- Centralized time programming via 6-order pilot wire
- Low standby power consumption (0.5 W)
- Can be controlled remotely via the box and the ENKI application
- Ultra-precise room thermostat to 1/10th of a degree
Operation of the product in the ENKI application:
Object functionality | Properties | Integration in a scenario | ||
Actions | Triggers | Conditions | ||
Change the target temperature of the thermostat |
Min: 7° / Max: 30° / Step: 0.5° |
✔ | ✘ | - |
Programming |
Via the heating menu |
✘ | ✘ | - |
Product view:
What does the radiator screen status mean:
Not paired with the ENKI box | Searching for signal | Paired with the ENKI box |
How do I calibrate my radiator?