Equation: Sorali connect - Product sheet

Séparateur horizontale vert.png

Prerequisites for installation and use :

* Prerequisites for the Enki application: Internet access and a phone with minimum operating system: Android: 7 / iOS: 15

Communication protocol:

  • Enocean

Available countries:

  • France

Status feedback available

  • Yes

Alexa voice control

  • Not direct, but possible via manual scenarios

Google Home voice control

  • Not direct, but possible via manual scenarios

Séparateur horizontale vert.png

Article content:

 

Technical description:

  • Type: Electric radiator with double connected heating system
  • Status feedback: Yes
  • Requires Enki box: Yes / ENKI Box V1
  • Power: 1000W, 1500W or 2000W
  • Color: White or silver gray
  • Dimensions: 1085 mm x 580 mm x 147 mm
  • Weight: 37 Kg
  • Adjustment accuracy (in °C): 0.5
  • Mains voltage: 230V AC 50 Hz
  • Insulation class: Class II
  • Water protection rating: IP24
  • Operating temperature: 0 to 50°C
  • Storage temperature: -20 to 70°C
  • Operating humidity: 0 to 85% without condensation
  • Regulation: Proportional and Integral
  • Temperature setting resolution: 0.5 °C, Digital
  • Safety thermostat trigger: 100 °C
  • Temperature range: 5° to 30°C
  • Stand-by consumption: < 0.5 W
  • Network protocol: EnOcean
  • Frequency band: 868 MHz
  • Maximum transmitted radio frequency power: 3 dBm

 

Product functionality in the ENKI application:

Device functionality Properties Scenario integration
Actions Triggers Conditions
Change the thermostat target temperature Min: 7° / Max: 30° / Step: 0.5°
Create an override Temporarily change the equipment temperature for a given time when it is in a program
Temperature logging

Logging of temperature readings by "day," "week," "month," and "year"

Programming Via the heating menu or individually via the control card
Check / Retrieve electrical consumption

Via cumulative consumption and consumption history (day, week, month, year)

Retrieve ambient temperature

Min: 0° / Max: 40° / Step: 0.1°

Equation Radiateur - Card N2 01.png Equation Radiateur - Card N2 02.png Equation Radiateur - Card N2 03.png Radiateur Acova Arlan - Card N2 03.png Programmation 01.png Programmation 02.png Equation Radiateur - Card N3.png
Control page Settings

 

Product view:

Radiateur Equation Sorali connect - Vue du produit.png

 

What does the radiator screen status mean:

 

Radiateur Sorali connect non connecté (cut).png Radiateur Sorali connect RF (cut).png

Radiator not paired with the Enki box

 

Radiateur Sorali connect connecté (cut).png Radiateur Sorali connect RF OK (cut).png

Radiator paired with the Enki box

 

Radiateur Sorali connect RF init (cut).gif Radiateur Sorali connect réception d'une trame (cut) (2).gif

Searching for signal to connect to the Enki box

 

Receiving or sending a signal (EnOcean frame) to the Enki box

 

Radiateur Sorali connect chauffe (cut).png Radiateur Sorali connect dérogation (cut).png

Heating in progress

 

Override activated (Manual mode) / The Enki box no longer controls

 

 

How to calibrate my device?

Radiateur Equation Sorali connect - Etalonnage du radiateur.png

 

How to reset my device?

Radiateur Sorali connect - Reset.png

How to reset (1).gif

 

Technical documents / user manual


Related articles

Submit a request