Technical Description:

  • Type: Connected dry contact module for boiler, garage door, gate, electrical outlet, and electric strike
  • Requires Enki box: Yes / ENKI Box V1
  • State feedback: Only for electrical outlet mode
  • Power supply: 230V AC 50 Hz
  • Maximum motor power: 2300 W (resistive load)
  • Operating temperature: from 0°C to 40°C
  • Dimensions: 40 mm (W) x 44 mm (L) x 16.9 mm (H)
  • Radio protocol: EnOcean
  • Central radio frequency: 868.3 MHz
  • Frequency band used: 868.0 to 868.6 MHz
  • Maximum radio power: +3dBm
  • Signal range: 20-30 meters indoors
  • EEP (EnOcean® Profile): D2-01-0F

 

Product Functionality in the ENKI Application:

Object Functionality Properties Scenario Integration
Actions Triggers Conditions
Turn On / Off Product On - Off function

Timer function:

Turn off in / Turn on in

Set a time during the day to switch the device "OFF" or "ON"

Timer function:

Cancel the timer

"STOP" the timer set for "Turn off in or turn on in"

Programming

Set a start time and device state

Set an end time and device state (optional)

Choose execution days

Chaudière - Card N2.png Lexman éclairage lumia filaire - Minuteur.png Programmation 01.png Programmation 02.png Chaudière - Card N3.png
Control Page Settings

 

Product View:

Vue du produit.png

 

What Does the LED Status of My Device Mean:

Rouge clignotant.gif Confirmation de réception de signal d'appairage.gif Module voyant vert.png Orange clignotant.gif
Flashing Red

Flashing Red

Flashes green twice

And solid green.

Solid Green Flashing Orange

Module in listening mode.

Ready to receive pairing signal from the Enki box

Detection of a pairing signal during listening phase.

Module powered / Standard state

(This does not mean it is paired with the ecosystem)

 Pre-reset phase

Waiting for confirmation for full reset

 

How to Reset My Device?