Equation: Dry Contact Connected Receiver - Product Sheet

Relais contact sec Equation - Photo.png

Séparateur horizontale vert.png

Prerequisites for installation and use:

* Prerequisites for the Enki app: Internet access and a phone with minimum operating system: Android: 7 / iOS: 15

Communication protocol:

  • Zigbee

Available countries:

  • France

State feedback available

  • Yes

Alexa voice control

  • Not directly, but possible via manual scenarios

Google Home voice control

  • Not directly, but possible via manual scenarios

Séparateur horizontale vert.png

Article content:

 

Technical description:

  • Type: Wired connected relay for boiler
  • Requires ENKI box: Yes / ENKI Box V1 - ENKI Connect Box
  • State feedback: Yes
  • Reference: BPS-SIN-4-1-20_EQU
  • Item code:
  • EAN code:
  • Power supply: 230V AC ~ 50 Hz
  • Switching capacity: 230V AC - 16A
  • Max power: 3680W - Zero crossing integrated
    Zéro Crossing.png
     
  • Consumption: <1W
  • Radio protocol: Zigbee 3.0
  • Radio frequency: 2.4 GHz
  • Zigbee frequency band: 2405 to 2480 MHz.
  • Maximum radio power: +10dBm
  • Range: Up to 10m indoors
  • Operating temperature: 0°C to 40°C
  • Protection rating: IP 20
  • Dimensions: 80 mm (l) x 93 mm (W) x 29.5 mm (h)
  • Weight: 134 g (excluding cables)
  • Cables provided: 2 flexible cables 2 x 0.75 mm2 - length 1.20 m
  • Color: White
  • Main material: Polycarbonate
  • Usage: Indoor
  • Warranty: 2 years

Hysteresis: -1°C / Setpoint / +1°C

What is it? It’s like a small "waiting zone" for your thermostat.

  • Instead of reacting exactly at the temperature you requested, it waits for the temperature to move a bit away from this setpoint before turning on or off.

In short: This prevents your boiler from turning on and off constantly for a very small temperature change, which is better for the device and your energy consumption!

A hysteresis of 1°C is a standard value and generally very suitable for most residential heating installations, offering a good balance between comfort, energy savings, and equipment preservation.

This value cannot be customized in our Enki application.

 

Product functionality in the ENKI app:

Device functionality Properties Scenario integration
Actions Triggers Conditions
Turn On / Off Product On - Off function
Associate regulators

Associate devices that can trigger the boiler

(Only compatible with the thermostat and Sedea thermostatic heads)

Minimum operating time

Set a minimum heating duration after activation.

Relais Equation - TB 01.png Relais Equation - TB 02.png Relais Equation - Card N2 01.png Relais Equation - Card N2 02.png Relais Equation - Card N2 03.png
Dashboard Settings

 

Product view:

Relais Equation - Vue du produit.png

 

What does the LED status of my device mean:

Relais Equation - Mode usine.gif Relais Equation - En cours d'enregistrement.gif Relais Equation - Connecté.png Relais Equation - Utilisation manuel.gif
Flashing yellow Slow flashing green Solid green Flashes twice after button press

Listening mode

Not connected

Box pairing signal detected

Registering

Usage mode

Connected or not listening

State change

Switches from Off to On or On to Off 

 

How to reset my device?

Relais Equation - Reset.gif

Relais Equation - How to reset..gif

 

Technical documents / user manual


Related articles

Submit a request