Prerequisites for Installation and Use:
- Enki Application
* Prerequisites for the Enki application: Internet access and a phone with minimum operating system: Android: 7 / iOS: 15
Communication Protocol:
- Wi-Fi
Available Countries:
- France
- Spain
- Italy
- Portugal
State Feedback Available:
- Yes
Alexa Voice Control:
- Not direct, but possible via manual scenarios
Google Home Voice Control:
- Not direct, but possible via manual scenarios
Article Content:
Technical Description
How to Install the Charging Station
Product Functionality in the ENKI Application
Product Overview
What Does the LED Status of My Product Mean?
How to Reset My Device?
Technical Documents / User Manual
Technical Description:
| Model | Reference | EAN |
| Charging Station 7/22 kW - T2S Socket | 90235808 | 3276007783483 |
| Charging Station 7 kW - T2 Cable | 90235807 | 3276007783476 |
| 90235808 | 90235807 | |
| T2S Socket | X | |
| Attached Cable (6.5m) with Holder | X | |
| Single-phase* | X | X |
| Three-phase* | X | |
| Dynamic Anti-Disconnection Load | X | X |
| Smartphone Application (Enki) | X | X |
| Connectivity |
Wi-Fi Ethernet |
Wi-Fi Ethernet |
| OCPP | 1.6J | 1.6J |
| Remote Update | X | X |
* Single-phase or three-phase configuration can be done during installation.
| Electrical Specification |
Maximum power: 22 kW (3P) / 7.4 kW (1P) Maximum current: 32A per phase, adjustable from 10A to 32A Nominal voltage (Un): 207-253 V~ (1P), 400V~ (3P) Operating frequency: 50 Hz Insulation voltage (Ui): 1.5kV L to N, 2kV L to L; 4kV L,N to ground Nominal impulse withstand voltage (Uimp): 4000 V Nominal peak withstand current (Ipk): 1500A Nominal short-time withstand current (Icw): 3kA Short-circuit current (Icc): 1000A 1 ms, 3 times Overvoltage category: III Pollution degree: 3 Electromagnetic compatibility classification (EMC): Type B Protection classification against electric shock: Class I Compatible neutral system: TNC-S, TNS Wi-Fi radio frequency band: 2.4 GHz Maximum radio transmission power: 20 dBm |
| Connector |
T2S Socket (90235808) Attached cable (6.5m) T2 connector (90235807) |
| Dynamic Anti-Disconnection Load Function |
TIC Interface (France) External smart meter with RS485 interface optional (Europe) |
| Display | LED strip indicator with dynamic pattern: Sound warning |
|
Enki Mobile Application (The Lexman charging station must be connected to the Internet) |
Start / Stop Charge status Usage and consumption history Remote access management to charging Charge unlocking Scheduling |
| Protection |
Internal protection: 6mA RCD-DD compliant with IEC 62955 Internal temperature derating Connector for current emission coil Required for installation (not included): Type A or Type F residual current circuit breaker, 30mA 6kA magnetic-thermal circuit breaker, curve C Cable gauge and section vary depending on site characteristics and local regulations 16A → protection rating = 20A Cable section = 6mm² 32A → protection rating = 40A Cable section = 10mm² |
| Mechanical |
Product dimensions: H455xW275xD151 Weight: ~4.5kg IP55 IK10 Material: PC / ASA Front color: RAL 9003 Back color: RAL 7024 Packaging: H460x W360x H250 (90235808) Packaging: H460x W360x H180 (90235807) |
| Mounting | Wall mounting plate |
| Optional Accessories |
Operating: -30 to 50°C, Humidity 5 to 95% (Power reduction may occur) Storage: -30/ 50°C Indoor and outdoor use Maximum altitude: 2500m |
| Interface |
Smart meter for load balancing Single-phase: SDM120CT-100A - Dynamic anti-disconnection load module for single-phase installation without TIC interface (France) Three-phase: SDM630MCT-100A Dynamic anti-disconnection load module for three-phase installation without TIC interface (France) |
| Interface | Ethernet, Wi-Fi, USB, Modbus RTU |
| Protocol |
OCPP 1.6j RS485 |
| 16A max/ phase | 32A max/ phase | |
| Rating | 20A | 40A |
| Cable Section | 6mm² | 10mm² |
To pair the device, your Wi-Fi network must be configured with WPA2 on the 2.4 GHz frequency.
If your 2.4 GHz Wi-Fi network is mixed with 5 GHz, 6 GHz, or 7 GHz frequencies, it is essential to separate the bands and assign a distinct SSID (Wi-Fi network name) to each frequency.
How to Install the Charging Station:
Product Functionality in the ENKI Application:
| Device Functionality | Properties | Scenario Integration | ||
| Actions | Triggers | Conditions | ||
| Start / Stop Charging | Charge or stop charging the car | ✔ | ✘ | ✘ |
| History | Check charging, connection, and disconnection history | ✘ | ✘ | ✘ |
| Remote Control | Allow remote control of the station | ✘ | ✘ | ✘ |
| Cable Unlock | Force unlocking of the charging cable from the station | ✘ | ✘ | ✘ |
| Check / Perform Available Updates | OTA update available |
✘ | ✘ | ✘ |
| Retrieve Firmware Version | Retrieve and display the current firmware version of the device |
✘ | ✘ | ✘ |
|
|
|
| Control Page | Settings |
Product Overview:
| Item | Part Description | Item | Part Description |
| 1 | Enclosure | 8 | Communication Board |
| 2 | Decorative Plate | 9 | LED Board |
| 3 | Front Cover | 10 | Charging Socket Power Supply |
| 4 | Flap | 11 | Contactor |
| 5 | Indicator Light | 12 | Lower Power Cable Entry |
| 6 | Charging Socket or Socket Holder | 13 | Upper Power Cable Entry |
| 7 | Power Board | 14 | Optional Signal Cable Entry 1 + 2 |
| The Lexman charging station is capable of charging any electric vehicle equipped with a type 2 connector |
What Does the LED Status of My Device Mean:
| Flashing Yellow | Flashing White and Green | Solid Green | Flashing Green | Solid Green, Flashing Blue | Blue Flowing Light |
|
Startup Or software update Duration: 1 to 5 minutes |
The station is ready to be initialized | The station is available. | Charging preparing | Ready to charge, waiting for authorization |
Charging in progress Or charging session started, waiting for the scheduled charging slot |
| Breathing Blue | Solid Blue | Solid Blue and Red | White flashing once every four seconds | Flashing Red | Solid Red |
| End of charge |
Charge scheduling activated |
Charger locked by the user from the configuration interface Note: This state is normally not accessible under normal conditions (use with ENKI connected station) |
Wi-Fi Hotspot activated (~1h) Connection to the configuration interface via Wi-Fi possible |
An error occurred, please retry the charging sequence. |
Internal error or incorrect installation Contact the installer or your reseller's customer service |
How to Reset My Device?
|
Perform a Reset of My Connected Device | ||
|
# Power off the station via the electrical meter. Open the charging station and set the power board selector to 9. Then restart the Lexman station, the indicator light will flash yellow. | ||
| Power off the station. | Set the selector to 9. | Power on the station. The light flashes yellow. |
|
# Wait five minutes. After this delay, power off the station again, then set the selector to the desired current. Finally, power on again. Your station has been successfully reset. | ||
| Wait 5 minutes. Then power off the station. | Set the selector to the desired current. | Power on the station. The station is reset. |