Prerequisites for installation and use:
- Enki Application
* Prerequisites for the Enki application: Internet access and a phone with a minimum operating system: Android: 7 / iOS: 15
Communication protocol:
- Cloud
Available countries:
- France
State feedback available:
- Yes
Alexa voice control:
- Not direct, but possible via manual scenarios
Google Home voice control:
- Not direct, but possible via manual scenarios
Article contents:
Technical description
Product functionality in the ENKI application
Product view
What does the LED status of my product mean?
How to reset my device?
Technical documents / user manual
Technical description:
- Type: Connected control center for electric pergola with adjustable slats
- Requires Enki box: No
- State feedback: Yes
- Radio protocol: IO
-
Radio frequency: 868 - 870 MHz, < 25 mW
- Radio range in open field: 80 m
- Native application: TaHoma by Somfy
-
Gateway required and recognized by Enki:
- TaHoma Switch
- Connectivity kit
- TaHoma DIN-Rail / TaHoma Rail-DIN S
- TaHoma Premium
- Connexoon
- Power supply: 24 Vdc SELV
-
Frequency bands and maximum power used:
- 868.000 MHz - 868.600 MHz e.r.p. <25 mW
- 868.700 MHz - 869.200 MHz e.r.p.<25 mW
- 869.700 MHz - 870.000 MHz e.r.p. <25 mW
- Protection rating: IP 65
- Electrical insulation: Class 3 (SELV 24V)
- Operating temperature: -20 °C to +60 °C
- Dimensions (L x W x H): 99 x 185 x 57 mm
-
Maximum number of control points and associated sensors:
- 3 maximum control points
- 9 maximum sensors
- Power supply: DC - RGE 11 - 24V
- Standby consumption: 0 W
- Maximum power: 288 W
- Current depending on switch 3: 2 x 3 A or 2 x 5.5 A
- Color/Finish: Gray
Product functionality in the ENKI application:
| Device functionality | Properties | Scenario integration | ||
| Actions | Triggers | Conditions | ||
| Open / Close | Min: 0% / Max: 100% / Step: 1% | ✔ | ✔ | ✔ |
| View roller shutter position | See roller shutter position in real time | ✘ | ✘ | ✘ |
| Control button | Up / Stop / Down | ✘ | ✘ | ✘ |
| Control page | Settings | |
Product view:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
What does the LED status of my device mean:
|
|||||||||||||||||||||||||||||||||||
|
Snow: Combination of rain and temperature information. (1): The proper functioning of the sensors depends on installation and maintenance conditions outdoors as close as possible to the pergola. Refer to the sensor manual before installation. (2) : The LED indicators will remain visible even if the sensors have been deactivated. | |||||||||||||||||||||||||||||||||||
How to reset my device?
| Perform a reset of my connected device | |
| # Press and hold the "PROG" button on the electronic board. After seven seconds, all indicators will light up. | |
| Press and hold the "PROG" button | After 7 sec. all indicators light up. |
| # Once all indicators are lit, release. The reset of the electronic board has been successfully completed. | |
| When all indicators are lit, release. The reset is successfully applied. | |