Prerequisites for installation and use:
- Enki Application*
* Prerequisites for the Enki application: Internet access and a phone with minimum operating system: Android: 7 / iOS: 15
Communication protocol:
- Cloud
Available country:
- France
State feedback available:
- Yes
Alexa voice control:
- Not direct, but possible via manual scenarios
Google Home voice control:
- Not direct, but possible via manual scenarios
Article contents:
Technical description
Product functionality in the ENKI application
Product view
What does the LED status of my product mean?
How to reset my device?
Technical documents / user manual
Technical description:
- Type: Connected pilot wire module for inertia electric heating
- Requires Enki box: No / Cozytouch connected Bridge mandatory
- State feedback: Yes
- Radio protocol: IO
- Radio frequency: 868 MHz
- Power supply: 230 VAC; 50 Hz; 0.1 A
- Pilot Wire Output: 0.05 A max, 230V
- Maximum Ambient Operating Temperature: 80°C
- Insulation: Class II
- Protection rating IP 24
- Dimensions: 135 x 70 x 22
- Manufacturer Name: Atlantic
- Compliant with RED directive 2014/53/EU
-
Frequency bands and maximum power used:
- 868.000 MHz - 868.600 MHz - e.r.p. <25 mW
- 868.700 MHz - 869.200 MHz - e.r.p. <25 mW
- 869.700 MHz - 870.000 MHz - e.r.p. <25 mW
- Certification body: EMITECH 0536
Product functionality in the ENKI application:
| Device functionality | Properties | Scenario integration | ||
| Actions | Triggers | Conditions | ||
| Change the target temperature mode of the thermostat | OFF / Frost protection / Economy / Comfort / Comfort -1 / Comfort -2 | ✔ | ✘ | ✘ |
| Programming | Via heating menu or unitary via the control board | ✘ | ✘ | ✘ |
| Control page | Settings | |
Product view:
| 1 | Indicator light | 2 | Connection button |
| L | Phase wire | N | Neutral wire | FP | Pilot wire |
What does the LED status of my device mean:
| Solid green | Flashing green very fast | Off | Solid red |
|
Not connected Device in factory mode. |
Not connected Searching for access point. |
Connected Product operational |
Error Malfunction related to wiring |
How to reset my device?
| Perform a reset of my connected device | |
| # Press and hold the connection button. (More than ten seconds) | |
| Press and hold the connection button | Hold for more than 10 sec. |
| # The module's green light turns on, release, the product is successfully reset. | |
|
After 10 sec. the light turns on, release! The product has been successfully reset. | |