Evology - Connected On/Off Electric Socket Receiver - Product Sheet

Photo.png

Séparateur horizontale vert.png

Prerequisites for installation and use :

* Prerequisites for the Enki app: Internet access and a phone with minimum operating system: Android: 7 / iOS: 15

Communication protocol:

  • Enocean

Available country:

  • France

State feedback available

  • Yes

Alexa voice control

  • Yes

Google Home voice control

  • Yes

Séparateur horizontale vert.png

Article contents:

 

Technical description:

  • Type: Connected dry contact module for boiler, garage door, gate, electric socket, and electric strike
  • Requires Enki box: Yes / ENKI Box V1
  • State feedback: Only for electric socket mode
  • Power supply: 230V AC 50 Hz
  • Maximum motor power: 2300 W (resistive load)
  • Operating temperature: 0°C to 40°C
  • Dimensions: 40 mm (w) x 44 mm (l) x 16.9 mm (h)
  • Radio protocol: EnOcean
  • Central radio frequency: 868.3 MHz
  • Frequency band used: 868.0 to 868.6 MHz
  • Maximum radio power: +3dBm
  • Signal range: 20-30 meters indoors
  • EEP (EnOcean® Profile): D2-01-0F

 

Product functionality in the ENKI app:

Device functionality Properties Scenario integration
Actions Triggers Conditions
Turn On / Off Product "ON" - "OFF" function

Timer function:

Turn off in / Turn on in

Set a time during the day to turn the device "OFF" or "ON"

Timer function:

Cancel timer

"STOP" the timer set for "Turn off in or turn on in"

Scheduling

Set a start time and device state

Set an end time and device state (optional)

Choose execution days

Module On, Off - Card N2.png Lexman éclairage lumia filaire - Minuteur.png Programmation 01.png Programmation 02.png Module On, Off - Card N3.png
Control page Settings

 

Product view:

Vue du produit.png

 

What does the LED status of my device mean:

Rouge clignotant.gif Confirmation de réception de signal d'appairage.gif Module voyant vert.png Orange clignotant.gif
Blinking red

Blinking red

Blinks twice green

And steady green.

Steady green Blinking orange

Module in listening phase.

Ready to capture pairing signal from the Enki box

Detection of a pairing signal during listening phase.

Module powered / Standard state

(This does not mean it is associated with the ecosystem)

 Pre-reset phase

Waiting for confirmation for full reset

 

How to reset my device?

Reset.png

How to reset.gif

 

Technical documents / user manual