Avidsen: Boiler Heating Module - Product Sheet

Photo.png

Séparateur horizontale vert.png

Prerequisites for installation and use:

* Prerequisites for the Enki app: Internet access and a phone with minimum operating system: Android: 7 / iOS: 15

Communication protocol:

  • Enocean

Available country:

  • France

State feedback available

  • Yes

Alexa voice control

  • Not direct, but possible via manual scenarios

Google Home voice control

  • Not direct, but possible via manual scenarios

Séparateur horizontale vert.png

Article content:

 

Technical description:

  • Type: Connected receiver for boiler.
  • Requires Enki box: Yes / Enki Box V1
  • State feedback: Yes
  • Size: 55 mm x 120 mm x 24 mm
  • Maximum device power: controlled 1150 W – 5 A
  • Features:
    • ON/OFF control of the boiler
    • Repeater function
  • Connection: To be connected to the boiler thermostat control input or to the circulator power supply
  • Cable section: Up to 2.5 mm²
  • Indoor use only
  • Operating temperature: 0 °C/+40 °C
  • Storage temperature: -20 °C/+70 °C
  • Power supply: 230 Vac / 50 Hz
  • Average consumption: < 1 W
  • Installation: surface wall mounting (anchors and screws provided)
  • Color: Sand / Pure white
  • Protection: IP20
  • Weight: 80 g
  • Radio profile:
    • Radio protocol: EnOcean / Profile D2-O1-O1
    • Radio frequency: 868.3 MHz
    • Data rate: 125 kbit/s
    • Modulation: ASK
    • Transmission power: +5 dBm (EIRP)
    • Radio range (Theoretical values provided by the manufacturer):
      • In open field: 30m
      • Masonry: 20m, through up to 3 walls
      • Reinforced concrete: 10m, through one wall/ceiling max.
      • Drywall/Wood: 30m, through up to five walls

 

Product functionality in the ENKI app:

Device functionality Properties Scenario integration
Actions Triggers Conditions
Turn On / Off Product On - Off function

Timer function:

Turn off in / Turn on in

Set a time during the day to turn the device "OFF" or "ON"

Timer function:

Cancel timer

"STOP" the timer set for "Turn off in or turn on in"

Programming

Set a start time and the device state

Set an end time and the device state (optional)

Choose execution days

Chaudière - Card N2.png Lexman éclairage lumia filaire - Minuteur.png Programmation 01.png Programmation 02.png Chaudière - Card N3.png
Control page Settings

 

Product view:

Module chaudière Avidsen - Vue du produit.png

 

What does the LED status of my device mean:

Allumé.png Paramètres de l'objet.gif Signal d'appairage détecté.gif Eteint.png
Light on Slow blinking Blinks 10 times very quickly then turns off Light off
Boiler on Device settings Pairing in progress. Pairing signal detected Boiler off

 

How to reset my device?

Module chaudière Avidsen - Reset.png

How to reset.gif

 

Technical documents / user manual