Prerequisites for installation and use:
- Enki App* + Enki Box
* Prerequisites for the Enki app: Internet access and a phone with minimum operating system: Android: 7 / iOS: 15
Communication protocol:
- Enocean
Available countries:
- France
State feedback available:
- Yes
Alexa voice control:
- Not direct, but possible via manual scenarios
Google Home voice control:
- Not direct, but possible via manual scenarios
Article content:
Technical description
Product functionality in the ENKI app
Product view
What does the LED status of my product mean?
How to reset my device?
Technical documents / user manual
Technical description:
- Type: Connected receiver for electric heating pilot wire
- Requires Enki box: Yes / ENKI Box V1
- State feedback: Yes
- Size: 55 mm x 120 mm x 24 mm
- Maximum power of controlled device: 3680 W - 16 A
- Measurement of active power consumed: in W or kW, Measurement accuracy: 1%
-
Features:
- Control of 6 radiator commands
- Energy consumption feedback since last power-on (in J, Wh or kWh)
- Repeater function
- Connection: To be connected between mains power and radiator
- Cable section: Up to 2.5 mm²
- Use: Indoor only
- Operating temperature: 0°C/+40°C
- Storage temperature: -20°C/+70°C
- Power supply: 230 Vac / 50 Hz
- Average consumption: < 1W
- Installation: wall-mounted, surface-mounted (anchors and screws provided)
- Color: Sand / Pure white
- Protection: IP20
- Weight: 80g
-
Radio profile:
- Radio protocol: EnOcean / Profile D2-O1-OC
- Radio frequency: 868.3 MHz
- Data rate: 125 kbit/s
- Modulation: ASK
- Transmission power: +5 dBm (EIRP)
-
Radio range:
- In open field: 80m
- Masonry: 20m, through max 3 walls
- Reinforced concrete: 10m, through max 1 wall/ceiling
- Drywall/Wood: 30m, through max 5 walls
Product functionality in the ENKI app:
| Device functionality | Properties | Scenario integration | ||
| Actions | Triggers | Conditions | ||
| Change the target temperature mode of the thermostat | OFF / Frost protection / Eco / Comfort / Comfort -1 / Comfort -2 | ✔ | ✔ | ✔ |
| Create an override | Temporarily change the equipment temperature for a given time when it is in a schedule | ✘ | ✘ | ✘ |
| Programming | Via the heating menu or individually via the control card | ✘ | ✘ | ✘ |
| Check / Retrieve electrical consumption | Via cumulative consumption and consumption history (day, week, month, year) |
✘ | ✘ | ✘ |
|
|
|
| Control page | Settings |
Product view:
What does the LED status of the module mean:
| Comfort mode, comfort -1 or Comfort -2 activated | Eco mode activated | Frost protection mode activated | Device settings |
Pairing in progress Pairing signal detected |
How to reset my device?