Prerequisites for installation and use:
- Enki App* + Enki Box or Enki Connect Box / Essentiel b Connect Box
* Prerequisites for the Enki app: Internet access and a phone with minimum operating system: Android: 7 / iOS: 15
Communication protocol:
- Zigbee
Available countries:
- France**
- Spain
- Italy
- Portugal
**Essentiel b Connect Box available only in France
State feedback available:
- Yes
Alexa voice control:
- No
Google Home voice control:
- No
Article content:
Technical description
Product functionality in the ENKI app
Product view
What does the LED status of my product mean?
How to reset my device?
Technical documents / user manual
Technical description:
| Detector SNZB-02 | Detector SNZB-02P | |
|
|
|
|
| Detector SNZB-02D | ||
|
||
Product functionality in the ENKI app:
| Device functionality | Properties | Scenario integration | ||
| Actions | Triggers | Conditions | ||
| Retrieve ambient temperature | Min: 0°C / Max: 40°C / Step 0.1°C | ✘ | ✔ | ✔ |
| Retrieve ambient humidity | Min: 0% / Max: 100% / Step 0.1% | ✘ | ✔ | ✔ |
| Temperature history | History by "day", "week", "month" and "year" | ✘ | ✘ | ✘ |
| Humidity history | History by "day", "week", "month" and "year" | ✘ | ✘ | ✘ |
| Allow push notifications | Receive notifications via the app about device status | ✘ | ✘ | ✘ |
| Battery level detection |
Battery level indication Receive notification in case of low battery (if push notifications enabled). Low battery badge on device |
✘ | ✔ | ✔ |
|
|
||
| Control page | Settings | |
Product view:
| Detector SNZB-02 | Detector SNZB-02P |
| Detector SNZB-02D | |
What does the LED status of my device mean:
| Detector SNZB-02 |
| Flashes three times quickly |
|
Not paired Searching for signal for pairing for the next 30 seconds. |
| Detector SNZB-02P | |
| Flashes slowly continuously | Flashes slowly, then quickly, and turns off |
|
Not paired Searching for signal for pairing |
Paired Pairing signal detected, registering |
| Detector SNZB-02D | ||||
| Simple display | Snowflakes | Flame | Drops | Sun |
|
Not connected Local operation |
Too cold Temperature ≤ 19°C |
Too hot Temperature ≥ 27℃ |
Too humid Humidity ≥ 60% RH |
Too dry Humidity ≤ 40% RH |
| Flashing empty battery | Flashing signal | Flashing then steady signal | Steady signal |
|
Low battery Replace the battery |
Not connected Pairing in progress, searching for the smart home box signal |
Connected Pairing signal detected. Registering |
Connected Device functional in your ecosystem |
How to reset my device?
| Detector SNZB-02 | Detector SNZB-02P |
| Detector SNZB-02D | |